Für das kommende L4T 5.1.1 wurden einige Änderungen vorgenommen. Diese findet ihr im Changelog.
Changelog
hekate v6.0.5 changes * L4T: Add BPMP-FW support for T210 (power management). * L4T: Add fine tuned DRAM voltage selection via ram_oc_vdd2 and ram_oc_vddq. * More info will be in the L4T 5.1.1 config readme. Nyx changes: * Lite Gamepad Calibration dumping * The Joycon BT pairing dump button can now be used to dump calibration data for Lite Gamepad. (Used in L4T 5.1.1, not yet released.) * Now eMMC errors will always be reported in eMMC info, even if eMMC init fails. * Updated DRAM info about 2 of the 3 newer ram chips (not yet validated). BDK Changes: * MINERVA: Fixed an issue where the wrong number of tables could be used. * MINERVA: Normalize selected frequency. This allows user to not be precise on ram freq for l4t. * MINERVA: Add support for 1966MHz (1958.4) and 2033MHz (2035.2). * DRAM: Add support for custom dram id 7 for T210 (7 is easy to burn on top of any T210 ids). This is for 8GB ram chips. * DRAM: Name 2 of the 3 new ram chips (Not yet validated, but an educated guess, since all previous ones were correct in the end.) * DRAM: Corrected SKU info about mid cycle Hynix RAM chips. * PMIC: Reduced max allowed dram voltage for new L4T dram support to be inside official limits. * TIMER: A new isleep function was added that allows instruction timed based sleep. * SDMMC: Fixed an issue where the wrong error reason was reported for the calibration pad for SD/eMMC.